Schneider Electric TeSys D LC1D Contactor is designed for reliable motor control and electrical switching in industrial low-voltage systems. With AC-3 rated current options from 9 A to 150 A, the series supports a wide range of motor applications. Its flexible coil voltage options, auxiliary contact configurations and compatibility with thermal overload relays make it suitable for industrial machinery, pumping systems, HVAC equipment and automated production lines.

  • Supports AC-1, AC-3 and other applicable utilization categories for different motor and electrical load requirements.
  • Offers multiple AC and DC coil voltage options, with auxiliary contacts and control accessories for various automation systems.
  • Compatible with TeSys thermal overload relays and circuit protection devices for coordinated motor starter assemblies.

The Schneider Electric TeSys D LC1D Contactor series is designed for motor control and electrical switching in low-voltage industrial systems. Covering AC-3 rated operational currents from 9 A to 150 A, the series offers multiple contactor ratings, coil voltage options and switching configurations to accommodate different motor and load requirements. Featuring reliable electromagnetic operation, integrated auxiliary contacts on standard configurations and compatibility with thermal overload relays, TeSys D LC1D contactors provide flexible solutions for motor starting, stopping and general industrial power control.

Motor Control and Switching Performance

The TeSys D LC1D series is designed for switching three-phase motors and controlling resistive electrical loads. It supports different utilization categories to accommodate various operating conditions:

  • AC-1: Switching non-inductive or slightly inductive loads, including resistive heating equipment.

  • AC-3: Starting squirrel-cage motors and switching them off during normal running conditions.

  • AC-4: More demanding motor operations, including inching, plugging and frequent reversing, where supported by the selected model.

The electromagnetic operating mechanism provides reliable contact opening and closing in response to control circuit signals, making the series suitable for motor control circuits and industrial automation systems.

Flexible Coil Voltage and Control Options

The LC1D series offers multiple AC and DC coil voltage options to match different control circuit requirements. Depending on the selected model, available coil configurations include standard AC coils, standard DC coils and low-consumption electronic coil versions. These options allow integration with different control power supplies, PLC systems and industrial control panels.

Selected models also feature wide-range electronic coils, supporting flexible control voltage requirements. Coil voltage and control circuit specifications should be matched to the actual electrical installation.

Compact Design and Auxiliary Contact Functions

Designed for integration into industrial electrical control panels, the TeSys D contactor features a compact electromagnetic structure and clearly arranged power and control terminals. Standard configurations commonly include 1 NO and 1 NC auxiliary contacts for electrical interlocking, control circuit feedback and contactor status indication.

Additional auxiliary contact blocks, mechanical interlocks and coil suppression modules are available for selected models. These accessories provide greater flexibility for reversing motor starters, sequential control circuits and other industrial switching arrangements.

Integration with Motor Protection Systems

The TeSys D LC1D series can be combined with compatible TeSys thermal overload relays to form direct-on-line motor starter assemblies. The contactor performs motor switching, while the overload relay provides protection against sustained motor overload conditions and phase-related faults, depending on the selected relay.

Compatible circuit breakers or fuses can also be incorporated to provide short-circuit protection. This combination supports coordinated motor control and protection in industrial electrical installations.

Industrial Applications

The TeSys D LC1D Contactor series is suitable for motor switching and electrical control across a wide range of industrial applications. Typical uses include:

  • Industrial Motor Control: Starting and stopping three-phase motors in manufacturing equipment.

  • Pumping Systems: Switching industrial water pumps, circulation pumps and process pumping equipment.

  • HVAC Systems: Controlling compressors, ventilation fans and air conditioning equipment.

  • Conveyor Systems: Motor switching for material handling and production line equipment.

  • Heating Equipment: Switching resistive heating loads and industrial thermal equipment.

  • Process Machinery: Electrical control of motors in packaging, processing and automated production systems.

Model Selection and Technical Specifications

The TeSys D LC1D series covers multiple contactor ratings to accommodate different motor power and electrical switching requirements.

  • Model Range: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38, LC1D40, LC1D50, LC1D65, LC1D80, LC1D95, LC1D115 and LC1D150.

  • Rated Operational Current: 9–150 A under AC-3 utilization, depending on the selected model.

  • Utilization Categories: AC-1, AC-3, AC-3e and AC-4, depending on the product reference.

  • Pole Configuration: Primarily 3-pole (3P) configurations, with additional TeSys D family variants available.

  • Rated Operational Voltage: Up to 690 V AC for many standard models, with higher-voltage ratings available for selected references.

  • Coil Voltage: Multiple AC and DC control voltage options.

  • Auxiliary Contacts: Integrated auxiliary contacts on standard configurations, with additional contact blocks available.

  • Installation: DIN-rail or panel mounting, depending on contactor size and model.

  • Compatible Accessories: Auxiliary contact blocks, mechanical interlocks, coil suppressors and compatible thermal overload relays.

Parameter

Item Specification
Series TeSys Deca LC1D
Product type 3-pole electromagnetic contactor
Utilization categories AC-3 for motor loads; AC-1 for non-inductive or slightly inductive loads
Rated operational current AC-3: 9-620 A at Ue <= 440 V; AC-1: up to 1000 A at ambient temperature <= 60 C
Maximum rated operational voltage 690 V for LC1D09-LC1D95; 1000 V for LC1D115-LC1D620
Standard motor power 2.2-200 kW at 220/240 V; 4-335 kW at 380/400 V; 5.5-450 kW at 660/690 V
Auxiliary contacts 1 NO + 1 NC instantaneous auxiliary contact built in on LC1D09-LC1D95; add-on instantaneous and time-delay modules available according to model
Control coil AC or DC, depending on model and complete ordering reference
Overload relay coordination Compatible TeSys thermal or electronic overload relay selected according to motor current and contactor frame
Mounting DIN-rail or screw mounting on selected smaller frames; panel or screw mounting on larger frames
Front protection IP20 protective cover
Ordering reference Complete the base model with the required coil-voltage code

Model Table

Base Model AC-3 Current AC-1 Current Motor Power Maximum Ue
Ue <= 440 V Ambient <= 60 C 380/400 V
LC1D09 9 A 25 A 4 kW 690 V
LC1D12 12 A 25 A 5.5 kW 690 V
LC1D18 18 A 32 A 7.5 kW 690 V
LC1D25 25 A 40 A 11 kW 690 V
LC1D32 32 A 50 A 15 kW 690 V
LC1D38 38 A 50 A 18.5 kW 690 V
LC1D40A 40 A 60 A 18.5 kW 690 V
LC1D50A 50 A 80 A 22 kW 690 V
LC1D65A 65 A 80 A 30 kW 690 V
LC1D80 80 A 125 A 37 kW 690 V
LC1D95 95 A 125 A 45 kW 690 V
LC1D115 115 A 200 A 55 kW 1000 V
LC1D150 150 A 200 A 75 kW 1000 V
LC1D170 170 A 200 A 90 kW 1000 V
LC1D205 205 A 275 A 110 kW 1000 V
LC1D245 245 A 315 A 132 kW 1000 V
LC1D300 300 A 400 A 160 kW 1000 V
LC1D410 410 A 500 A 220 kW 1000 V
LC1D475 475 A 700 A 265 kW 1000 V
LC1D620 620 A 1000 A 335 kW 1000 V

Model or Frame W x H x D Approx. Weight Mounting
LC1D09-LC1D18 45 x 77 x 86 mm 0.320-0.330 kg 35 mm DIN rail or screw fixing
LC1D25-LC1D38 45 x 85 x 92 mm 0.370-0.380 kg 35 mm DIN rail or screw fixing
LC1D40A-LC1D65A 55 x 122 x 120 mm 0.850-0.860 kg 35 mm DIN rail or screw fixing
LC1D80-LC1D95 85 x 127 x 130 mm 1.590-1.610 kg 35/75 mm DIN rail or screw fixing
LC1D115-LC1D170 120 x 158 x 136 mm 2.500 kg DIN-rail arrangement or screw fixing
LC1D205 168.5 x 174 x 181 mm 5.20 kg Panel or screw mounting
LC1D245 168.5 x 197 x 181 mm 5.30 kg Panel or screw mounting
LC1D300 213 x 206 x 219 mm 9.35 kg Panel or screw mounting
LC1D410 213 x 206 x 219 mm 10.05 kg Panel or screw mounting
LC1D475 233 x 238 x 232 mm 12.50 kg Panel or screw mounting
LC1D620 309 x 464 x 255 mm 20.10 kg Panel or screw mounting

Recommended Products

Schneider ATV930 & ATV950 Variable Frequency Drives

Schneider ATV930 & ATV950 Variable Frequency Drives

Schneider Altivar Process ATV930 and ATV950 variable frequency drives are designed for variable-speed control of pumps, fans, compressors, conveyors and other industrial process equipment. ATV930 covers wall-mounted, open-type and floor-standing configurations, while ATV950 provides IP55 wall-mounted and IP54 floor-standing versions for more demanding environments.
Schneider TeSys F LC1F Contactor

Schneider TeSys F LC1F Contactor

Schneider TeSys F LC1F contactors are heavy-duty industrial contactors for motor starting and high-current power switching. The TeSys F family covers AC-3 motor-control ratings from 115 A to 1000 A and AC-1 switching ratings up to 2600 A, with multiple coil, pole and voltage configurations for demanding industrial applications.
Schneider TeSys Giga LC1G Contactor

Schneider TeSys Giga LC1G Contactor

Schneider TeSys Giga LC1G contactors are high-power contactors for TeSys motor control applications, covering 115 A to 800 A AC-3. The series uses electronic wide-band coil control, compact modular construction and built-in diagnostic functions to simplify installation, maintenance and stock management.

Latest News

How to Choose a Schneider MCB?

How to Choose a Schneider MCB?

Choose a Schneider MCB by matching its rated current to the load and cable, selecting the correct pole configuration, and verifying its breaking capacity and trip curve.
What Is Schneider Masterpact NW? Features, Ratings and Applications

What Is Schneider Masterpact NW? Features, Ratings and Applications

Schneider Masterpact NW is a low-voltage air circuit breaker (ACB) range rated from 800 A to 6300 A, designed to protect high-current electrical distribution systems.
How to Choose a Masterpact NW Air Circuit Breaker?

How to Choose a Masterpact NW Air Circuit Breaker?

Choose a Masterpact NW ACB by matching its rated current and breaking capacity to the electrical system, then selecting suitable protection and installation options.
SCHNEIDER ELECTRIC & ABB

Products & Solutions for Your Project

Jiahong brings together Schneider Electric and ABB products and sourcing services for your project, from individual items to coordinated product packages.

  • Product identification & selection
  • Cross-reference review
  • Product packages & sourcing coordination

Tell Us What You Need

GET A QUOTE

+86 18066257292

+86 18066257292

sales@jiahongelec.com