Schneider-HVX-Medium-Voltage-Vacuum-Circuit-Breaker-1
Schneider-HVX-Medium-Voltage-Vacuum-Circuit-Breaker-1 Schneider-HVX-Medium-Voltage-Vacuum-Circuit-Breaker-2 Schneider-HVX-Medium-Voltage-Vacuum-Circuit-Breaker-3

Schneider HVX Medium-Voltage Vacuum Circuit Breaker

Schneider Electric HVX is a modular medium-voltage vacuum circuit breaker designed for mainstream air-insulated switchgear. The series covers 12 kV, 24 kV and 40.5 kV voltage classes, with listed short-circuit breaking capacities from 25 kA to 50 kA and rated currents from 630 A to 4000 A, plus a 5000 A option on the specified 12 kV model. Fixed and withdrawable versions are described in the supplied product content.

  • Broad Voltage Coverage: 12 kV, 24 kV and 40.5 kV versions support a range of medium-voltage distribution requirements.
  • Sealed Vacuum Poles: The vacuum interrupter, primary circuit and insulation rod are encapsulated in epoxy on the described design.
  • Spring Operating Mechanism: Manual and electric spring charging and anti-misoperation interlocks support reliable switching.
  • Fixed or Withdrawable: Withdrawable versions support truck arrangements, with an electric truck option and door interlock by configuration.
  • Switchgear Integration: Designed for air-insulated switchgear; interchangeable installation is described for equivalent standard products, subject to interface verification.

The Schneider Electric HVX Medium-Voltage Vacuum Circuit Breaker (VCB) is designed for indoor medium-voltage power distribution systems, providing reliable switching and short-circuit interruption for electrical networks up to 24 kV. With rated current options from 630 A to 4,000 A and short-circuit breaking capacities of 25 kA, 31.5 kA, 40 kA and 50 kA, the HVX series offers flexible configurations for different switchgear requirements. Featuring vacuum interruption technology, a robust operating mechanism and fixed or withdrawable installation options, the HVX series is suitable for utility substations, industrial facilities and medium-voltage distribution networks.

Vacuum Interruption Technology and Electrical Performance

The HVX series uses vacuum interrupters to extinguish electrical arcs during circuit interruption. The vacuum switching technology provides effective insulation and arc interruption, supporting reliable operation under normal switching and short-circuit fault conditions. Its design helps reduce contact erosion and maintenance requirements while supporting repeated switching operations. The circuit breaker works with compatible protection relays and current transformers to provide coordinated fault detection and circuit interruption within medium-voltage distribution systems.

Reliable Operating Mechanism and Safety Design

Designed for demanding medium-voltage applications, the HVX series features a robust operating mechanism and insulated pole structure. The vacuum interrupter is integrated into a protective pole assembly, providing mechanical support and electrical insulation. Mechanical and electrical interlocking arrangements help prevent incorrect switching operations and improve operational safety. Selected configurations also support remote operation and remote racking, allowing operators to control circuit breaker movements from a separate operating position.

Flexible Installation and Switchgear Integration

The Schneider HVX series is available in fixed and withdrawable configurations to accommodate different medium-voltage switchgear designs. Withdrawable versions can be mounted on an isolating truck or compatible racking system, facilitating insertion, removal and maintenance. The series supports integration into Schneider Electric medium-voltage switchgear platforms and panel builder designs, with different connection arrangements and accessory options available according to the selected configuration.

Applications in Medium-Voltage Power Distribution

The HVX Medium-Voltage Vacuum Circuit Breaker is suitable for switching and protection applications across a wide range of industrial and utility power systems. Typical applications include:

  • Power Distribution Substations: Circuit protection and switching for medium-voltage incoming and outgoing feeders.

  • Power Generation: Switching and protection in power plant auxiliary distribution systems.

  • Oil and Gas: Medium-voltage distribution for processing facilities and industrial electrical networks.

  • Mining and Metals: Protection of electrical distribution systems in mining and metal processing facilities.

  • Chemical Industry: Switching and protection for industrial power distribution networks.

  • Marine and Infrastructure: Medium-voltage switching applications in marine facilities and critical infrastructure.

Parameter

Item Specification
Series HVX medium-voltage vacuum circuit breaker
Voltage Classes 12 kV / 24 kV / 40.5 kV
Rated Frequency 50 / 60 Hz
Short-Circuit Breaking Capacity 12 kV: 25–50 kA; 24 kV: 25–40 kA; 40.5 kV: 25–31.5 kA
Rated Current 12 kV: 630–4000 A, with specified 5000 A option; 24 kV: 630–4000 A; 40.5 kV: 1250–3150 A
Insulation Level 12 kV: 42 kV power-frequency / 75 kV impulse; 24 kV: 65 / 125 kV; 40.5 kV: 95 / 185 kV
Mounting Fixed or withdrawable
Pole Spacing 12 kV: 150 / 210 / 275 mm; 24 kV: by model; 40.5 kV: 275 / 300 / 440 mm by version
Operating Conditions Ambient −25°C to +40°C; standard altitude 1000 m; higher altitude on request
Humidity 24-hour average ≤95% RH; monthly average ≤90% RH
Standards GB/T 1984, GB/T 11022, DL/T 402, DL/T 403, IEC 62271-100 and IEC 62271-1
Typical Applications Overhead lines, cables, motors, transformers, generators and capacitor banks

Model Table

Model Family Voltage Breaking Capacity Rated Current Additional Reference
HVX12-25 12 kV 25 kA 630 / 1250 / 1600 / 2000 / 2500 / 3150 / 4000 A* Peak 63 kA; 4 s short-time withstand 25 kA
HVX12-31 12 kV 31.5 kA 630 / 1250 / 1600 / 2000 / 2500 / 3150 / 4000 A* Peak 80 kA; 4 s short-time withstand 31.5 kA
HVX12-40 12 kV 40 kA 1250 / 1600 / 2000 / 2500 / 3150 / 4000 A* Peak 100 kA; 4 s short-time withstand 40 kA
HVX12-50 12 kV 50 kA 1250 / 1600 / 2000 / 2500 / 3150 / 4000 A* Peak 125 kA; 4 s short-time withstand 50 kA
HVX12-50-50/K 12 kV 50 kA 5000 A* Only 5000 A model listed; peak 150 kA
HVX24-25 / -31 24 kV 25 / 31.5 kA 630–4000 A by version Higher-current versions may require forced-air cooling
HVX24-40 24 kV 40 kA 1250–4000 A by version Pole spacing 275 mm listed
HVX40-25 40.5 kV 25 kA 1250–3150 A Insulation level 95 / 185 kV
HVX40-31 40.5 kV 31.5 kA 1250–3150 A Pole spacing 275 / 300 / 440 mm by version

Wiring Diagram

Dimensional Drawings

Recommended Products

Schneider Electric ComPacT NSX MCCB

Schneider Electric ComPacT NSX MCCB

ComPacT NSX is Schneider Electric’s molded case circuit breaker family for distribution and critical-power applications. The core NSX100–NSX630 range covers 100–630 A in 3P and 4P configurations, with several frame sizes, breaking-capacity classes and thermal-magnetic or electronic trip-unit options. Compact NSX100m/160m versions extend the family to smaller ratings, while an NSX800 AC version is listed separately. Broad Protection Options: TM-D / TM-G thermal-magnetic units, MA magnetic units, TAM overloa
Schneider Electric Acti9 Pro iC65 & iDPN MCB

Schneider Electric Acti9 Pro iC65 & iDPN MCB

Acti9 Pro is Schneider Electric’s fifth-generation modular terminal-distribution platform, introduced in the supplied product content as a 2025-generation range. It combines iC65 miniature circuit breakers for 1P–4P circuits with compact iDPN 1P+N breakers for single-phase final circuits. The family includes 6 kA and 10 kA iC65 versions and iDPN variants with breaking capacities up to 10 kA.
Schneider Electric EvoPacT HVX Medium-Voltage VCB

Schneider Electric EvoPacT HVX Medium-Voltage VCB

EvoPacT HVX is Schneider Electric’s next-generation digital-native medium-voltage vacuum circuit breaker, with 12 kV and 24 kV versions described in the supplied product-page content. It combines vacuum switching with optional digital monitoring modules and sensors for breaker-health monitoring, contact-wear visibility and remote operation. Listed short-circuit breaking capacities are 25, 31.5 and 40 kA, depending on voltage class and model.
ATV320 Variable Frequency Drive

ATV320 Variable Frequency Drive

Schneider ATV320 variable frequency drives are designed for open-loop control of three-phase asynchronous and synchronous motors in industrial machinery. The range covers 0.18–22 kW and includes compact IP20, book-style IP20, IP66 and IP65 versions. Built-in communication includes Modbus serial and CANopen, with optional industrial Ethernet and fieldbus modules.

Latest News

How to Choose a Schneider MCB?

How to Choose a Schneider MCB?

Choose a Schneider MCB by matching its rated current to the load and cable, selecting the correct pole configuration, and verifying its breaking capacity and trip curve.
What Is Schneider Masterpact NW? Features, Ratings and Applications

What Is Schneider Masterpact NW? Features, Ratings and Applications

Schneider Masterpact NW is a low-voltage air circuit breaker (ACB) range rated from 800 A to 6300 A, designed to protect high-current electrical distribution systems.
How to Choose a Masterpact NW Air Circuit Breaker?

How to Choose a Masterpact NW Air Circuit Breaker?

Choose a Masterpact NW ACB by matching its rated current and breaking capacity to the electrical system, then selecting suitable protection and installation options.
SCHNEIDER ELECTRIC & ABB

Products & Solutions for Your Project

Jiahong brings together Schneider Electric and ABB products and sourcing services for your project, from individual items to coordinated product packages.

  • Product identification & selection
  • Cross-reference review
  • Product packages & sourcing coordination

Tell Us What You Need

GET A QUOTE

+86 18066257292

+86 18066257292

sales@jiahongelec.com