Schneider Electric Altistart ATS22 is a three-phase soft starter for controlled starting and stopping of squirrel-cage asynchronous motors. It combines three-phase control, an integrated bypass contactor, motor protection and Modbus communication in a compact unit.
Schneider Altistart ATS22 Soft Starter
- Motor & Supply Range: 4–400 kW motor range; Q models use 230–440 V, while S6/S6U models use 208–600 V, 50/60 Hz.
- Integrated Bypass: The built-in bypass reduces heat dissipation and simplifies wiring; the catalog states 6 power terminals instead of 12.
- Controlled Start & Stop: Configurable voltage ramp and torque control, with freewheel stop or controlled deceleration.
- Motor Protection: Thermal protection, PTC sensor input, overload/underload and overcurrent monitoring, plus phase-sequence and phase-loss detection.
- Setup & Integration: 4-digit display, 4 LEDs, 4 navigation keys, 3 programmable logic inputs, 2 NO/NC relay outputs and Modbus serial communication.
The Schneider Electric Altistart 22 ATS22 Soft Starter is designed for soft starting and stopping of three-phase asynchronous motors, particularly in pump and fan applications. With rated current options from 17 A to 590 A and operating voltage ratings from 208 V to 600 V, the series covers motor power applications up to 400 kW, depending on the selected model and supply voltage. Featuring voltage and torque control, an integrated bypass function, motor thermal protection and Modbus communication, the ATS22 provides a practical motor starting solution that helps reduce electrical and mechanical stress while simplifying motor control system design.
Controlled Starting and Stopping
The ATS22 combines voltage and torque control to provide smooth motor acceleration and deceleration. Its current-limiting function supports controlled motor startup, with a maximum current limitation of approximately 3.5 times the starter rated current for the referenced configurations. Adjustable starting torque, acceleration time and stopping parameters allow users to adapt motor operation to different load conditions. These functions are particularly useful in pumping systems where controlled stopping helps reduce pressure fluctuations and water hammer.
Integrated Bypass and Motor Protection
The ATS22 features an integrated bypass function that connects the motor to the supply after the starting phase is completed. This reduces power losses in the thyristor section during normal motor operation and helps simplify the external power circuit. Integrated motor thermal protection also supports motor protection during operation, while configurable monitoring functions help identify abnormal operating conditions.
Communication and Control Integration
The Altistart 22 supports Modbus serial communication for integration with compatible PLCs and industrial automation systems. Its control interface includes configurable inputs and relay outputs for motor operation, running status, fault indication and other control requirements. SoMove software compatibility allows users to configure operating parameters and transfer settings between compatible devices.
Industrial Applications
The ATS22 is primarily designed for standard-duty industrial applications involving pumps and fans. Other suitable applications include compressors, conveyors, turbines, escalators, ventilation systems and general industrial machinery requiring reduced-voltage motor starting and controlled stopping.
Model Selection and Technical Specifications
-
Rated Operational Voltage: 208–600 V AC.
-
Rated Operational Current: 17–590 A.
-
Motor Power: 4–400 kW, depending on model and supply voltage.
-
Motor Compatibility: Three-phase squirrel-cage asynchronous motors.
-
Control Technology: Voltage and torque control.
-
Current Limitation: Up to approximately 3.5 × starter rated current for referenced configurations.
-
Integrated Function: Internal bypass.
-
Protection: Integrated motor thermal protection.
-
Communication: Modbus serial communication.
-
Applications: Pumps, fans, compressors, conveyors and general industrial machinery.
Parameter
| Item | Specification |
| Series | Altistart ATS22 |
| Motor Type | Three-phase squirrel-cage asynchronous motor |
| Motor Power Range | 4–400 kW; actual rating depends on model, supply voltage and connection method |
| Supply Voltage | ATS22...Q: 230–440 V AC; ATS22...S6 / S6U: 208–600 V AC |
| Supply Frequency | 50/60 Hz |
| Control Supply | Q and S6 versions: 220 V; S6U version: 110 V |
| Controlled Phases | 3-phase control |
| Control Method | Configurable voltage ramp and torque control |
| Stop Modes | Freewheel stop or controlled deceleration ramp |
| Bypass | Integrated bypass contactor |
| Protection Functions | Motor and starter thermal protection, PTC input, overload/underload, overcurrent, phase-sequence and phase-loss detection |
| Additional Monitoring | Phase-imbalance and leakage-current monitoring on S6 / S6U versions |
| Control I/O | 3 programmable logic inputs; 2 programmable NO/NC relay outputs |
| Communication | Modbus serial communication via RJ45 |
| Display & Setup | 4-digit display, 4 LEDs, 4 navigation keys; SoMove configuration software |
| Protection Rating | D17–C11: IP20 (IP00 without connections); C14–C59: IP00 |
| Standards | IEC/EN 60947-4-2; EMC Class A; RoHS |
Model Table
| Model | Rated Current (A) | Motor Power Rating | Dimensions (W × D × H) | Weight (kg) |
| ATS22D17Q | 17 | 4 / 7.5 / 7.5 | 130 × 169 × 265 mm | 7 |
| ATS22D32Q | 32 | 7.5 / 15 / 15 | 130 × 169 × 265 mm | 7 |
| ATS22D47Q | 47 | 11 / 22 / 22 | 130 × 169 × 265 mm | 7 |
| ATS22D62Q | 62 | 15 / 30 / 30 | 145 × 207 × 295 mm | 12 |
| ATS22D75Q | 75 | 18.5 / 37 / 37 | 145 × 207 × 295 mm | 12 |
| ATS22D88Q | 88 | 22 / 45 / 45 | 145 × 207 × 295 mm | 12 |
| ATS22C11Q | 110 | 30 / 55 / 55 | 150 × 229 × 356 mm | 18 |
| ATS22C14Q | 140 | 37 / 75 / 75 | 150 × 229 × 356 mm | 18 |
| ATS22C17Q | 170 | 45 / 90 / 90 | 150 × 229 × 356 mm | 18 |
| ATS22C21Q | 210 | 55 / 110 / 110 | 206 × 299 × 425 mm | 33 |
| ATS22C25Q | 250 | 75 / 132 / 132 | 206 × 299 × 425 mm | 33 |
| ATS22C32Q | 320 | 90 / 160 / 160 | 206 × 299 × 425 mm | 33 |
| ATS22C41Q | 410 | 110 / 220 / 220 | 206 × 299 × 425 mm | 33 |
| ATS22C48Q | 480 | 132 / 250 / 250 | 304 × 340 × 455 mm | 50 |
| ATS22C59Q | 590 | 160 / 315 / 355 | 304 × 340 × 455 mm | 50 |
| ATS22D17Q | 17 | 5.5 / 11 / 15 | 130 × 169 × 265 mm | 7 |
| ATS22D32Q | 32 | 11 / 22 / 22 | 130 × 169 × 265 mm | 7 |
| ATS22D47Q | 47 | 18.5 / 45 / 45 | 130 × 169 × 265 mm | 7 |
| ATS22D62Q | 62 | 22 / 55 / 55 | 145 × 207 × 295 mm | 12 |
| ATS22D75Q | 75 | 30 / 55 / 75 | 145 × 207 × 295 mm | 12 |
| ATS22D88Q | 88 | 37 / 75 / 75 | 145 × 207 × 295 mm | 12 |
| ATS22C11Q | 110 | 45 / 90 / 90 | 150 × 229 × 356 mm | 18 |
| ATS22C14Q | 140 | 55 / 110 / 110 | 150 × 229 × 356 mm | 18 |
| ATS22C17Q | 170 | 75 / 132 / 132 | 150 × 229 × 356 mm | 18 |
| ATS22C21Q | 210 | 90 / 160 / 160 | 206 × 299 × 425 mm | 33 |
| ATS22C25Q | 250 | 110 / 220 / 220 | 206 × 299 × 425 mm | 33 |
| ATS22C32Q | 320 | 132 / 250 / 250 | 206 × 299 × 425 mm | 33 |
| ATS22C41Q | 410 | 160 / 315 / 355 | 206 × 299 × 425 mm | 33 |
| ATS22C48Q | 480 | 220 / 355 / 400 | 304 × 340 × 455 mm | 50 |
| ATS22C59Q | 590 | 250 / 400 / 500 | 304 × 340 × 455 mm | 50 |
| ATS22D17S6 | 17 | 4 / 7.5 / 7.5 / 9 | 130 × 169 × 265 mm | 7 |
| ATS22D32S6 | 32 | 7.5 / 15 / 15 / 18.5 | 130 × 169 × 265 mm | 7 |
| ATS22D47S6 | 47 | 11 / 22 / 22 / 30 | 130 × 169 × 265 mm | 7 |
| ATS22D62S6 | 62 | 15 / 30 / 30 / 37 | 145 × 207 × 295 mm | 12 |
| ATS22D75S6 | 75 | 18.5 / 37 / 37 / 45 | 145 × 207 × 295 mm | 12 |
| ATS22D88S6 | 88 | 22 / 45 / 45 / 55 | 145 × 207 × 295 mm | 12 |
| ATS22C11S6 | 110 | 30 / 55 / 55 / 75 | 150 × 229 × 356 mm | 18 |
| ATS22C14S6 | 140 | 37 / 75 / 75 / 90 | 150 × 229 × 356 mm | 18 |
| ATS22C17S6 | 170 | 45 / 90 / 90 / 110 | 150 × 229 × 356 mm | 18 |
| ATS22C21S6 | 210 | 55 / 110 / 110 / 132 | 206 × 299 × 425 mm | 33 |
| ATS22C25S6 | 250 | 75 / 132 / 132 / 160 | 206 × 299 × 425 mm | 33 |
| ATS22C32S6 | 320 | 90 / 160 / 160 / 220 | 206 × 299 × 425 mm | 33 |
| ATS22C41S6 | 410 | 110 / 220 / 220 / 250 | 206 × 299 × 425 mm | 33 |
| ATS22C48S6 | 480 | 132 / 250 / 250 / 315 | 304 × 340 × 455 mm | 50 |
| ATS22C59S6 | 590 | 160 / 315 / 355 / 400 | 304 × 340 × 455 mm | 50 |
| ATS22D17S6U | 17 | 3 / 5 / 10 / 15 | 130 × 169 × 265 mm | 7 |
| ATS22D32S6U | 32 | 7.5 / 10 / 20 / 25 | 130 × 169 × 265 mm | 7 |
| ATS22D47S6U | 47 | — / 15 / 30 / 40 | 130 × 169 × 265 mm | 7 |
| ATS22D62S6U | 62 | 15 / 20 / 40 / 50 | 145 × 207 × 295 mm | 12 |
| ATS22D75S6U | 75 | 20 / 25 / 50 / 60 | 145 × 207 × 295 mm | 12 |
| ATS22D88S6U | 88 | 25 / 30 / 60 / 75 | 145 × 207 × 295 mm | 12 |
| ATS22C11S6U | 110 | 30 / 40 / 75 / 100 | 150 × 229 × 356 mm | 18 |
| ATS22C14S6U | 140 | 40 / 50 / 100 / 125 | 150 × 229 × 356 mm | 18 |
| ATS22C17S6U | 170 | 50 / 60 / 125 / 150 | 150 × 229 × 356 mm | 18 |
| ATS22C21S6U | 210 | 60 / 75 / 150 / 200 | 206 × 299 × 425 mm | 33 |
| ATS22C25S6U | 250 | 75 / 100 / 200 / 250 | 206 × 299 × 425 mm | 33 |
| ATS22C32S6U | 320 | 100 / 125 / 250 / 300 | 206 × 299 × 425 mm | 33 |
| ATS22C41S6U | 410 | 125 / 150 / 300 / 350 | 206 × 299 × 425 mm | 33 |
| ATS22C48S6U | 480 | 150 / — / 350 / 400 | 304 × 340 × 455 mm | 50 |
| ATS22C59S6U | 590 | — / 200 / 400 / 500 | 304 × 340 × 455 mm | 50 |
Wiring Diagram
The following diagrams summarize typical ATS22 wiring references in one clean combined graphic for website product documentation.
Recommended Products
ABB SACE Tmax XT Molded Case Circuit Breakers
Schneider Masterpact NW 08-63 Air Circuit Breaker
Schneider Altistart ATS48 Soft Starter
Schneider Altistart ATS480 Soft Starter
Latest News
How to Choose a Schneider MCB?
What Is Schneider Masterpact NW? Features, Ratings and Applications
How to Choose a Masterpact NW Air Circuit Breaker?
SCHNEIDER ELECTRIC & ABB
Products & Solutions for Your Project
Jiahong brings together Schneider Electric and ABB products and sourcing services for your project, from individual items to coordinated product packages.
- Product identification & selection
- Cross-reference review
- Product packages & sourcing coordination