EasyPact MVS is Schneider Electric's low voltage air circuit breaker series designed for reliable protection and switching in power distribution systems. The series covers 630A to 4000A ratings with fixed and draw-out configurations for industrial plants, commercial buildings and main power distribution.
Schneider EasyPact MVS 06-40 Air Circuit Breaker
- Rated Current: 630A–4000A
- Poles: 3P / 4P
- Mounting Type: Fixed / Draw-out
- Applications: Main distribution and industrial power systems
The Schneider Electric EasyPact MVS06–MVS40 Air Circuit Breaker (ACB) is designed for low-voltage power distribution systems, providing circuit protection and switching functions for high-current electrical applications. Covering rated currents from 630 A to 4,000 A, the series offers multiple frame sizes and breaking capacity options to meet different installation requirements. With electronic ET, ETA and ETV trip systems, flexible mounting configurations and a range of operating accessories, EasyPact MVS supports reliable power distribution in industrial and commercial facilities.
Electronic Protection and Trip Unit Functions
The EasyPact MVS series is equipped with ET, ETA and ETV electronic trip systems, offering different levels of circuit protection and electrical measurement. Depending on the selected trip unit, protection functions include long-time overload protection, short-time and instantaneous short-circuit protection, and ground-fault protection. ETA and ETV versions also provide electrical measurement capabilities, with ETV supporting both current and energy measurements. These functions help operators monitor electrical conditions and manage power distribution more effectively.
Flexible Installation and Operating Configurations
Available in fixed-mounted and drawout versions, the EasyPact MVS06–MVS40 series can be integrated into different low-voltage switchboard designs. Three-pole and four-pole configurations provide flexibility for various power distribution systems. Drawout models feature connected, test and disconnected positions, facilitating circuit isolation, inspection and maintenance. The stored-energy operating mechanism supports manual or electrical operation, with compatible accessories available for remote opening, closing and status indication.
Breaking Capacity and Protection Coordination
The EasyPact MVS range offers different breaking capacity versions to accommodate varying short-circuit levels in electrical distribution networks. Its electronic trip systems provide adjustable protection settings to support coordination between upstream and downstream circuit breakers. Depending on the selected configuration, short-time protection and zone-selective interlocking (ZSI) functions can help improve protection selectivity and reduce unnecessary interruptions across the distribution system.
Applications
The EasyPact MVS06–MVS40 Air Circuit Breaker is suitable for main incoming protection, outgoing feeder protection and bus-coupler applications in low-voltage electrical distribution systems. Typical installations include industrial plants, commercial buildings, infrastructure projects, power distribution panels and large electrical switchboards requiring high-current switching and circuit protection.
Model Selection and Technical Specifications
The EasyPact MVS06–MVS40 series covers rated current options from 630 A to 4,000 A across multiple frame sizes. When selecting a suitable model, key parameters include rated current, rated operational voltage, ultimate breaking capacity (Icu), service breaking capacity (Ics), short-time withstand current (Icw), pole configuration, mounting type and electronic trip system. Additional accessories, including motorized operating mechanisms, auxiliary contacts and communication interfaces, can be selected according to the switchboard design and operational requirements.
Parameter
| Parameter | Specification |
| Series | EasyPact MVS |
| Rated Current | 630A / 800A / 1000A / 1250A / 1600A / 2000A / 2500A / 3200A / 4000A |
| Poles | 3P / 4P |
| Installation | Fixed / Draw-out |
| Rated Voltage | Up to 690V AC |
| Standard | IEC 60947-2 |
Model Table
| Model | Rated Current | Poles | Mounting |
| MVS06 | 630A | 3P / 4P | Fixed / Draw-out |
| MVS08 | 800A | 3P / 4P | Fixed / Draw-out |
| MVS10 | 1000A | 3P / 4P | Fixed / Draw-out |
| MVS12 | 1250A | 3P / 4P | Fixed / Draw-out |
| MVS16 | 1600A | 3P / 4P | Fixed / Draw-out |
| MVS20 | 2000A | 3P / 4P | Fixed / Draw-out |
| MVS25 | 2500A | 3P / 4P | Fixed / Draw-out |
| MVS32 | 3200A | 3P / 4P | Fixed / Draw-out |
| MVS40 | 4000A | 3P / 4P | Fixed / Draw-out |
Wiring Diagram






Recommended Products
Schneider TeSys Giga LC1G Contactor
Schneider Masterpact MTZ 08-63 Air Circuit Breaker
Schneider Masterpact NT 06-16 Air Circuit Breaker
ABB SACE FORMULA Molded Case Circuit Breakers
Latest News
How to Choose a Schneider MCB?
What Is Schneider Masterpact NW? Features, Ratings and Applications
How to Choose a Masterpact NW Air Circuit Breaker?
SCHNEIDER ELECTRIC & ABB
Products & Solutions for Your Project
Jiahong brings together Schneider Electric and ABB products and sourcing services for your project, from individual items to coordinated product packages.
- Product identification & selection
- Cross-reference review
- Product packages & sourcing coordination